NexCOBOT Taiwan
13F, No.916, Zhongzheng Rd., Zhonghe Dist., New Taipei City, Taiwan 23586, R.O.C.
TEL: +886-2-8226-7786
Schneider LXM32MU45M2
Servo Drive
Motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.15/0.3kWDescription
Main Features
Range of product |
Lexium 32 |
Product or component type |
Motion servo drive |
Device short name |
LXM32M |
Format of the drive |
Book |
Network number of phases |
Single phase |
[Us] rated supply voltage |
100...120 V - 15...10 % 200...240 V - 15...10 % |
Supply voltage limits |
170…264 V 85…132 V |
Supply frequency |
50/60 Hz - 5...5 % |
Network frequency |
47.5...63 Hz |
EMC filter |
Integrated |
Continuous output current |
1.5 A at 8 kHz |
Output current 3s peak |
3 A at 115 V for 5 s 4.5 A at 230 V for 5 s |
Continuous power |
150 W at 115 V 500 W at 230 V |
Nominal power |
0.15 KW at 115 V 8 kHz 0.3 KW at 230 V 8 kHz |
Line current |
2.6 A 85 % at 115 V, with external line choke of 5 mH 3.4 A 100 % at 230 V, with external line choke of 5 mH 2.9 A 173 % at 115 V, without line choke 2.9 A 181 % at 230 V, without line choke |
Technical
Environment
Electromagnetic compatibility |
Conducted EMC, class A group 1 conforming to EN 55011 Conducted EMC, class A group 2 conforming to EN 55011 Conducted EMC, environment 2 category C3 conforming to EN/IEC 61800-3 Conducted EMC, category C2 conforming to EN/IEC 61800-3 Conducted EMC, environments 1 and 2 conforming to EN/IEC 61800-3 Electrostatic discharge immunity test, level 3 conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields, level 3 conforming to EN/IEC 61000-4-3 1.2/50 µs shock waves immunity test, level 3 conforming to EN/IEC 61000-4-5 Electrical fast transient/burst immunity test, level 4 conforming-to EN/IEC 61000-4-4 Radiated EMC, class A group 2 conforming to EN 55011 Radiated EMC, category C3 conforming to EN/IEC 61800-3 |
Standards |
EN/IEC 61800-5-1 EN/IEC 61800-3 |
Product certifications |
CSA UL TÜV RoHS |
IP degree of protection |
IP20 conforming to EN/IEC 60529 IP20 conforming to EN/IEC 61800-5-1 |
Vibration resistance |
1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance |
15 gn for 11 ms conforming to EN/IEC 60028-2-27 |
Pollution degree |
2 conforming to EN/IEC 61800-5-1 |
Environmental characteristic |
Classes 3C1 conforming to IEC 60721-3-3 |
Relative humidity |
Class 3K3 (5 to 85 %) without condensation conforming to IEC 60721-3-3 |
Ambient air temperature for operation |
0…50 °C conforming to UL |
Ambient air temperature for storage |
-25…70 °C |
Type of cooling |
Natural convection |
Operating altitude |
<= 1000 m without > 1000...3000 m with conditions |